What the camera saw in the flue, and what puts it right

Price the repairs

On the screen

The camera rises from the smoke chamber. Healthy clay tile shows as smooth, square sections with thin, even joints. At the fifth joint the line is dark and wide where mortar has washed out. Two tiles higher a hairline runs up one face of the tile and widens toward the top. Near the cap the walls are black and glossy. Those three frames are the most common reasons a flue fails, and each one points to a different repair.

Every finding on our report is tied to a frame like these, with its height in the flue, so whoever pays for the repair can see exactly what it fixes.

Flue findings and their usual fixes

Open joints and cracked tile let heat and smoke reach the brick, and in a frame house the wood beyond it. The usual fix is a stainless liner run from the appliance to the top, which turns the old tile into a sleeve. Where a flue has no liner at all, as in some older brick chimneys, the same fix applies. A liner is sized to the flue and the appliance, so its price comes to you in writing once we have measured.

Glossy black buildup near the top tells us the flue has run cool and the fuel has been burning poorly. It needs removing before anyone can judge the tile under it, and the cause, often a flue too large for what it serves, is noted with the fix.

  • Washed-out joints or split tile: stainless liner, written figure after measuring
  • No liner in a brick flue: liner fitted, same basis
  • Heavy buildup: sweep, from $425, with the tile judged afterward
  • Open top with debris inside: cap fitted, quoted after we measure

Switching instead of relining

On rental property, many owners take a failed wood flue as the moment to go to gas. A sealed gas insert brings its own liner to the top, so the old tile no longer carries anything. Fitted into an existing firebox it runs $2,800 to $5,650, and it puts that unit on the same yearly gas check as the rest of the building.

Water that reaches the flue

Washed-out joints rarely happen without water. When the footage shows them, we look for how the water got in: an open top, a cracked crown, or metal at the roofline that has lifted. Leak tracing and repair are priced from $565 to $3,400. A wide chimney holding water on its high side may need a small sloped diverter, from $455 to $1,020, or $680 to $1,700 with the step flashing renewed. Crown, damper and chase-lid work gets a written figure from us once seen.

Figures for the usual fixes

Our installed prices for the repairs that follow most failed flues. Anything not listed gets a written figure from us before work starts. Caps work differently, since we price one only after the flue has been measured.

Water path found and stopped
$565 to $3,400
Sloped diverter behind a wide stack
$455 to $1,020
Diverter plus renewed roofline metal
$680 to $1,700
Sealed gas unit in place of a wood flue
$2,800 to $5,650
Follow-up camera run after repair
$395
Top for an open flue, fitted
Quoted after we measure

Liners, crowns, dampers and chase lids are measured before they are priced, so they carry no list figure here.

Questions after a failed flue

Does a cracked tile always mean a rebuild?

No. Where the brick around the flue is sound, a liner usually puts the flue right without taking the chimney down.

Why is there no price for a liner?

Its cost turns on the flue size, the height and what it connects to. We measure first and send the figure in writing.

Can we keep using the fireplace until the repair?

The report says so for each fireplace. A cracked or open flue is usually marked keep off until fixed.

Do you show that the repair was done?

Yes. A follow-up camera run after the work adds footage of the finished flue to the same file.

We have footage from another company. Can you price from it?

Often, for the items it shows clearly. We tell you which findings we can price from it and which we need to see ourselves.

A failed flue on your report?

Send the address and what the report flagged through the contact page, and we will set out the repairs in order with the figures we can give.

Call (949) 879-2607
Call (949) 879-2607